00073
Carrier Transicold
Critical

No A/C Power – Check Cord

The unit is in electric mode but detects no power input from the external grid.

Possible causes

  • Improperly connected power cord
  • Tripped charging station circuit breaker
  • Burnt plug or socket
  • Equipment power transformer failure

Recommended actions

  • Secure connection at both ends of the cord
  • Check main wall/station switch
  • Switch to Diesel mode to protect cargo
  • Measure voltage at electric contactor input

Can't find your code? Talk to an expert