00071
Carrier Transicold
Critical

Bad F2 or F3 Fuse

Failure in fuses F2 or F3 which control vital accessory power circuits.

Possible causes

  • Short circuit in evaporator fans
  • Failed heating solenoid
  • Electrical overload in auxiliary circuits
  • Wiring rubbing against chassis

Recommended actions

  • Visually inspect F2 and F3 fuses
  • Measure resistance of associated solenoids
  • Replace fuse with correct amperage rating
  • Trace wires for rub-through or burnt points