00061
Carrier Transicold
Warning

Door Open

The sensor indicates a compartment door is open, stopping the unit.

Possible causes

  • Improperly closed door
  • Faulty magnetic door switch
  • Missing or broken door magnet
  • Short circuit in door wiring harness

Recommended actions

  • Close all doors firmly
  • Check for presence of magnets on door leaves
  • Verify magnetic sensor condition
  • Inspect connector condition at the top of the frame