00056
Carrier Transicold
Warning

Check Evaporator Air Flow

The system has detected a significant restriction in airflow through the evaporator.

Possible causes

  • Evaporator coil clogged by dirt or ice
  • Failed evaporator fan motors
  • Fallen or blocked internal air ducts
  • Fan belts (if applicable) slipping or broken

Recommended actions

  • Perform a full manual defrost
  • Inspect evaporator coil cleanliness
  • Verify fan motor rotation
  • Ensure cargo does not block return air